Vista de página 0
#6011ML • 10/2001
PRINTED IN U.S .A .
INSTALLATION & SERVICE MANUAL
W164 N9221 Water Street
-
PO Box 450
-
Menomonee Falls, Wisconsin 53052-0450 U.S.A.
PHONE: 262.251.3800 FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY WEBSITE:
800.558.8744
U.S.A./CANADA 262.251.1907 INTERNATIONAL www.alto-shaam.com
C
o
m
b
i
t
h
e
r
m
G
A
S
®
Gas-Fired
Combination
Oven/Steamer
United States
& Canada
®
Models:
6•10ML
7•14ML
10•10ML
10•20ML
12•18ML
20•20ML
Vista de página 0
1 2 3 4 5 6 ... 26 27

Resumo do Conteúdo

Página 1 - Oven/Steamer

#6011ML • 10/2001PRINTED IN U.S .A .INSTALLATION & SERVICE MANUALW164 N9221 Water Street -PO Box 450 -Menomonee Falls, Wisconsin 53052-0450 U.S.A

Página 2 - COMBITHERM

The gas units units are equipped with intermittent pilot-basedoperation and are fitted with a Honeywell gas valve. The gasvalve has a built-in pressu

Página 3 - FOUR/CONVECTION VAPEUR

Installation and Service Manual #6011ML • 7.Thermostat Calls forHeat• Pilot Valve/Ignition Off• Wait for Flame Signal toDisappear• Pilot Valve Closes

Página 4

CHECK LIST✔ Transport damage?✔ No gas hose/tube under the burner?✔ No flexible gas line or tubing under oven?✔ Non-combustible installation floor?✔ Mi

Página 5 - See Transportation Damage

Installation and Service Manual #6011ML • 9.2.0 - Combitherm Gas Operation SchematicCombitherm Gas Plumbing SystemWater is used for generating steam

Página 6 - 1.8 - ELECTRICAL CONNECTIONS

Installation and Service Manual #6011ML • 10.2.1 - SERVICE CONTRACTService • Section 2Alto-Shaam urges the user to maintain a record of service perfo

Página 7 - 1.12 - GAS EXHAUST

Installation and Service Manual #6011ML • 11.CONTROL TROUBLESHOOTING • ML Gas CombithermCall service.Controller defectiveID errorSoftware errorConne

Página 8 - 1.13 - P R ESSURE CHART

Installation and Service Manual #6011ML • 12.TROUBLESHOOTING • ML Gas CombithermAdditional malfunctions can occur during operation which do not res

Página 9 - 1.14 - GAS FLAME PATTERNS

Installation and Service Manual #6011ML • 13.EMERGENCY OPERATION • ML Gas CombithermIn the event of an error code, operation of the ML Gas Combithe

Página 10 - Installation • Section 1

Installation and Service Manual #6011ML • 14.PART DESCRIPTION 6•10GML 7•14GML 10•10GML 10•20GML 12•18GML 20•20GML1. Side Racks, Left SR-23585 SR-2384

Página 11 - SEQUENCE OF OPERATION

Installation and Service Manual #6011ML • 15.PART DESCRIPTION 6•10GML 7•14GML 10•10GML 10•20GML 12•18GML 20•20GML52. Gas Valve HSI (Propane) VA-33370

Página 12 - ✕ Did pilot ignite correctly?

COMBITHERMMODELS6•10ML, 7•14ML, 10•10ML, 10•20ML, 12•18ML & 20•20ML GASSAFETY:Do not store or use gasoline or other flammable vapors or liquidsin

Página 13 - ML • 9

Installation and Service Manual #6011ML • 16.Combitherm Model 10•20ML GasService • Section 22.6 - ML Gas Combitherm with Exterior ComponentsExhaust s

Página 14 - Service • Section 2

Installation and Service Manual #6011ML • 17.2.7 - ML Control Panel Operation POWER ON/OFF KEY STEAM MODE KEY PROGRAMMED MENU KEY COOKING TEMPERA

Página 15 - ML Gas Combitherm

2.8 - Left Side Components - Service ViewCombitherm 6•10ML, 7•14ML, 10•10ML, 10•20ML and 12•18ML GasBypass ProbeSound AbsorberWater NozzleMotorTransf

Página 16

Installation and Service Manual #6011ML • 19.2.8- Left Side Components – Combitherm 20•20ML Gas • Service ViewWaterNozzlesDisplay Control BoardMotor

Página 17

BypassBypassInstallation and Service Manual #6011ML • 20.20•20MLGAS2.9 - ML Gas Combitherm Service Views6•10ML7•14ML10•10ML10•20ML12•18MLGAS

Página 18

Installation and Service Manual #6011ML • 21.Service • Section 2

Página 19

Installation and Service Manual #6011ML • 22.Service • Section 2

Página 20 - ML • 16

TRANSPORTATION DAMAGE and CLAIMSAll Alto-Shaam equipment issold F.O.B. shipping point,and when accepted by the carrier, such shipments become the prop

Página 21 - ELECTRIC MODELS ONLY

Operation and Care Manual #6011 • 3.COMBITHERMFOUR/CONVECTION VAPEUR6•10ML, 7•14ML, 10•10ML, 10•20ML, 12•18ML & 20•20ML GASADVERTISSEMENTNe pas e

Página 22 - Combitherm 6•10

TABLE OF CONTENTSML Gas Combitherm Installation & Service ManualSECTION 1 - INSTALLATION1.1 Delivery/Unpacking . . . . . . . . . . . . . . . . .

Página 23

Upon receipt of the Combitherm ML Gas combinationoven/steamer, check the exterior of the shipping crate for anyphysical damage that could result in da

Página 24 - ML • 20

damage to the control components andwill void the warranty.Do not use circulating fans on thefloor as this will cause the loss of pilotflame and affec

Página 25

The installation of this oven must be done by a qualifiedinstaller familiar with the local codes and regulations governingthe installation of commerci

Página 26

The gas valve, pilot burner and nozzles for the main burner have been fitted according to the gas typespecified on the name plate. Technical specific

Página 27 - LIMITED WARRANTY

Installation and Service Manual #6011ML • 5.When starting the unit after initial installation, the gas lines must be free of air. It may take up to3