f.1 Power Switch
Fryer position turns ON the ventilator power light and blower.
If, within 10 seconds, there is sufficient air flow for proper
operation, the power light will remain ON and the fryer will
operate.
v.2 Ventilator Power
Turns ON when the fryer power switch is ON and adequate air
flow has been proven.
v.3 Check Filters Light
Turns ON when grease baffle and/or HEPA air filter are not
properly installed. When ON, the fryer heating elements are de-
activated and the fryer will not heat.
v.4 Replace Filters Light
Will turn ON if either the HEPA air filter or charcoal air filter are
due for replacement. The fryer will continue to operate, but the
air filter(s) must be changed in a timely manner or the unit will
clog, the service required light will turn ON, and the fryer will
shutdown until the filter(s) have been replaced.
v.5 Service Required Light
Will turn ON and the fryer will shut down whenever there is
insufficient ventilator air flow for proper operation.
v.6 Ventilator Blower
Provides air flow when running.
v.7 Fusible Link Locations
Provides fire protection by melting at a pre-determined
temperature and activating the fire suppression system.
v.8 Fire Suppression Nozzle(s)
Disperses the fire suppression media.
f.9 Oil Filter Pump Motor Overload Reset
Provides over-temperature protection for filter pump motor.
Must be manually reset by pushing in on the red button.
v.10 Ventilator Exhaust Collar
Allows for ventilator discharge. Do not block. Contains fire
damper with pre-installed 165°F fusible link.
v.11 Charcoal Filter
v.12 HEPA Air Filter
v.13 Grease Baffle
See Filters Installation section in this manual.
v.14 Fire Suppression System Status Indicator
Indicates status of Ansul fire suppression system (i.e., Cocked or
Fired).
v.15 Access to Autolift Motor
On VAE Model fryers equipped with automatic basket lift device.
v.16 Manual Pull Station
Allows manual discharge of fire suppression system.
v.17 Grease Cup
Catches drippings from grease baffle.
f.18 Drip Pan
Catches any liquid draining from top of fryer.
f.19 Stabilizer
Prevents the unit from tipping backwards.
f.20 Rigid (rear) Casters
Allows the unit to be easily positioned by slightly lifting the front
of the unit.
IMPORTANT: If a remote pull station is installed, both rear
casters (f.20) must be replaced with legs to deter
movement of the unit.
Moving an appliance with a
remote pull station will discharge the fire suppression
system.
f.21 Fixed (front) Legs
Operation and Care Manual #8452/53/55 • 4
NOTE:
Items beginning with
"f.."
are part of the fryer.
Items beginning with
"v.."
are part of the
ventilator.